IoT-Ensonga AI dry cooler for hyperscale data centers .

Mu masannyalaze amanene - aga minzaani, nga okukuuma ebbugumu erisinga obulungi eri ebyuma ebikulu kye kisinga obukulu, ekinyogovu ekikalu ekikoleddwa yinginiya olw’okusaba kw’omutindo ogw’amaanyi - okwetaagisa. Obusobozi bwayo okukwata ebiwujjo by’ebbugumu eringi, okutuuka ku 100 kW/m2, kifuula eky’obugagga ekikulu mu bifo ebikola amasannyalaze. Ekiwujjo ekinene - density finned - tube heat exchanger, nga kirimu ebiwaawaatiro 12 buli yinsi, kituuka ku mugerageranyo gw’okutambuza ebbugumu ogw’ekitalo ogwa 800 W/m2K, okukakasa okusaasaanya ebbugumu okulungi.
Ekinyogovu kino ekikalu kikola ku mazzi - enkola ya loopu ennyogovu, eggaddwa - n’amazzi agataliimu ayoni. Mu mabibiro g’amasannyalaze, dizayini eno ekendeeza ku bulabe bw’obutambuzi bw’amasannyalaze, okukuuma ebitundu by’amasannyalaze ebizibu n’enkola. Enyogoza bulungi ekinyogoza, n’ekendeeza ku bbugumu lyayo okuva ku 25℃okutuuka ku 15℃, ekintu ekyetaagisa mu nkola ennywevu ey’ebyuma eby’amaanyi eby’amaanyi ebya waggulu -, okufaananako n’engeri gye kiwagira GPU arrays ne CPU clusters mu mbeera za HPC.
Ensengeka ya ffaani etali ya maanyi egaba okulemererwa - okukola okw'obukuumi, okutangira okuggalawo okutali kwa bulijjo okuyinza okutaataaganya okukola amasannyalaze. Okugatta ku ekyo, ekisenge ky’amaloboozi kikendeeza ku maloboozi okutuuka ku 55 dB(a), ekitondekawo embeera y’okukola esinga okunyuma eri abaddukanya ebimera. Ekoleddwa ku masannyalaze amanene - aga minzaani, ekinyogovu kino ekikalu kikola kinene nnyo mu kukuuma obwesigwa n’obulungi bw’amasannyalaze - okuzaala enkola, okufaananako n’amakulu gaakyo mu kutendekebwa kwa AI n’okukoppa kwa ssaayansi munda mu bibinja bya HPC.
Ekoleddwa okukola kompyuta z’ebire ezisukkiridde, kino IoT-Eky’okugatta AI dry cooler egatta okuddaabiriza okuteebereza n’okulongoosa omulimu okwa nnamaddala-Okulongoosa omulimu. Ewagira okukola 24/7 mu bifo ebitereka amawulire, ebibinja bya HPC, n’ebyuma by’amasannyalaze ebinene-, okukwata ebiwujjo by’ebbugumu ebituuka ku 100 kW/m2 ate ng’ekuuma PUE < 1.15.
Ebikwata ku nsonga enkulu .
|
Parameter . |
Okusoggola |
|
Enkwata y’okufuuwa ebbugumu . |
100 kW/m2 (ekirungi ku racks za seva za density {1} . |
|
FINNED-Enkola ya Tube . |
12 ebiwaawaatiro buli yinsi, 800 W/m2·K Omugerageranyo gw’okutambuza ebbugumu . |
|
Ekisaawe ekinyogoza . |
Amazzi agataliimu ayoni (agaggaddwa-okunyogoza amazzi agalooka) . |
|
Ebbugumu eriri mu bbanga . |
Omulyango oguyingira: 25 Degree → Outlet: 15℃(±0.5℃precision) |
|
IoT okugatta . |
Okuyungibwa kwa 4G/LTE, AI Analytics dashiboodi . |
|
Omutendera gw’amaloboozi . |
55 dB(A) (Ekiyumba eky’amaloboozi kirimu) . |
Ebikwata ku by'ekikugu .
Obusobozi bwa IoT & AI .
◆ Okuddaabiriza okuteebereza: AI algorithms zeekenneenya ddala -data y’ebiseera (Fan speed, temperature differentials, vibration) okulagula okulemererwa essaawa 72 nga bukyali.
◆ Okutereka data ey’ebyafaayo kusobozesa okwekenneenya emitendera okusobola okuteekawo enteekateeka y’okuddaabiriza.
◆ Okulondoola okuva ewala: App y’oku ssimu ekkiriza ddala-Okulondoola obudde bwa PUE, emiwendo gy’okutambula kw’amazzi agabuguma, n’okukozesa amaanyi. Alerts trigger automatically for anomalies (okugeza, ebisengejja ebizibiddwa, fan failures).
Omutindo gw'okunyogoza .
◆ high-Okuwanyisiganya ebbugumu okw’amaanyi: ebiwaawaatiro 12 buli yinsi bisukkulumya obuwanvu bw’okungulu ate nga bukendeeza ku buziyiza bw’empewo. Dizayini ewagira okusaasaanya ebbugumu ku500+ server racks mu unit emu.
◆ Enkola ya ffaani etali ya maanyi: N+1 Ensengeka ya ffaani ekakasa okukola okutambula obutasalako mu kiseera ky’okuddaabiriza. Buli ffaani ayokya-Swappable, nga okukyusaamu okutwala<15 minutes.
Okukozesa amaanyi amalungi .
◆ Variable-Ebiwujjo by’embiro: EC Motors zitereeza sipiidi nga zeesigamiziddwa ku AI-okuteebereza omugugu oguvugirwa, okukendeeza ku maanyi agakozesebwa ebitundu 35% bw’ogeraageranya n’ebikozesebwa ebinywevu-eby’amangu.
◆ Okukekkereza amaanyi buli mwaka: $8,000+ buli yuniti (ku $0.12/kWh).
.
Enkola z'okukozesa .
◆ Ebifo eby’amawulire ebisukkiridde (hyperscale data centers): binyogoza 10,000+ seeva mu bifo eby’okukozesa kompyuta mu kire, okukuuma ebbugumu erisinga obulungi eri AWS/Azure-Emirimu egy’okugerageranya.
◆ Ebifo eby’okutendekebwamu HPC & AI: Ewagira okunyogoza eri GPU arrays mu AI research labs (okugeza, NVIDIA A100 clusters), okuziyiza thermal throttling mu kiseera ky’okutendekebwa mu kuyiga okw’obuziba.
◆ Amabibiro g’amasannyalaze aganene-aganyogoga ne jenereta, okukakasa okukola okutebenkedde mu bifo eby’ebbugumu, eby’amaanyi ga nukiriya, n’eby’amasannyalaze agazzibwawo.
Ebisaanyizo by'obusuubuzi .
◆ Ekika n'okukakasa: [CoolSmartTM], CE, ISO 9001, UL ewandiikiddwa
◆ MOQ: 1 unit (eteesebwako ku biragiro ebinene)
◆ Okuteeka emiwendo:
1-4 Yuniti: $25,000-$28,000/unit
Yuniti 5-10: $22,000-$25,000/unit
Okusasula: T/T (30% deposit), L/C nga olaba
Obudde bw’okukulembera: Ennaku 15-20 (ezikoleddwa), ennaku 7 (ebikozesebwa mu mutindo)
Okupakinga: Ebibokisi by’embaawo ebikakasibwa 15 (2200×1800×2000mm)
Ebirungi by'ebintu .
◆ AI-Obulung’amu obugobererwa: Ekendeeza ku budde obutategekeddwa ebitundu 90% okuyita mu kuddaabiriza okulagula, okukwatagana n’omutindo gw’omutendera ogw’ekiseera ogw’ekiseera III/IV.
◆ Modular scalability: Yuniti zisobola okufaanana okusobola okukwata emigugu gy’ebbugumu erituuka ku 10MW, nga kirungi nnyo okugaziya ekifo kya data.
.
.
Hot Tags .: Data center dry cooler, China data center dry cooler abakola, abagaba ebintu, ekkolero











